Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling Unit

Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling UnitGuangdong Head-Power Air Conditioning is a modernized professional enerprise engaging in the manufacture of cental air conditioners. Since we founded in 2001, based on social development needs , we are committed to upgrade of technological innovation, c

Featured Products

Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling Unit

Guangdong Head-Power Air Conditioning is a modernized professional enerprise engaging in the manufacture of cental air conditioners. Since we founded in 2001, based on social development needs , we are committed to upgrade of technological innovation, continuously forge ahead and create new brilliance. We has rich experience in design and manufacturing of refrigeration dehumidifiers.
All products have passed ISO 9001 Certificate and ISO 14001 Certificate, some  equipments have CE Certificate and CCS Certificate as well. Meanwhile, our company have a number of invention patents (Patent NO.: ZL200910246621.7,  ZL200910246620.2)  and utility model patents (Patent NO.: ZL201120547872.1, ZL201220043474.0, ZL201220124504.0, ZL2009920273841.4 and ZL200920273842.9), and participate in setting HVAC industry standards. Head-Power is also the secretariat of Guangdong HVAC and Purification Equipment Standardization Technical Committee.

Description:

1. Double skin galvanized steel sheet, aluminium alloy frame, 30mm thick PU insulation.  
2. This heat recovery unit  is mainly used for heat recovery and ventilation, combined with supply fan and motor, exhaust fan and motor, heat recovery wheel and filters.
3. Energy saving and improve indoor air quality: this fresh air unit can not only introduce fresh air to                improve indoor air quality, at the same time, it exchanges heat with exhaust air, which can precool for preheat fresh air, save much energy.
4. Cooling coil or heating coil is optional at supply air section to be heat recovery AHU. 
5. Silica-gel heat recovery wheel, full heat recovery, high efficiency up to 80%. 
6. Washable nylon prefilter or plate filter G4 is installed at air intake. Bag filter is optional.
7. Air volume: 1000 m3/h ~20000 m3/h. 
8. Standard power supply: 380~415V/3PH/50Hz.

 Advantages:
 
1. Heat and energy heat recovery, saving energy for building consumption. 
2. Introduce fresh air, exhaust polluted air, improvde indoor air quality;
3. Wide volume range, meet different requirements of industrial, commercial and residential building;
4. Good quality heat exchange device, high efficiency and long lifespan. 
5. Easy for maintainance and operation, low cost. 

High heat exchange efficiency

Advanced counter flow structure design is able to extend the module's heat exchange time, and the grid-style air vent greatly enhances the heat exchange area, therefore VM's heat exchange efficiency is 5%-10% higher than the cross flow unit.

Total heat recovery without pollution

The nanometer hole heat exchange film made of high polymer material enjoys excellent heat conductivity and moisture permeability, good air-tightness, total heat recovery without air pollution.

Sterilization

Exclusive heat exchange material formula has the function of sterilization.

Complete model types

The air quantity ranges from 500CMH to 140000CMH, sufficient meet user's requirements.

Long service life

ABS frame structure is firm and durable, has service life double that of the cross flow units.

Stable performance, easy maintenance, needs no cleaning

The streamlined design of VM module air vent is effective to prevent dust. When a primary filter is used, it shall be cleaned regularly in order to maintain the performance indexes of heat exchange efficiency, while the cross-flow units have to be cleaned frequently.

New high static-pressure double air-intake centrifugal fan

The new blades are improved wider and of larger curvature and diameter. When the most appropriate air flow passes, the static pressure is enhanced, while the noise is reduced. It's made of special material, resistant to high or low temperature and tensile. It's designed to be a perfect combination of high static-pressure, low noise and high reliability.
 
Paper Core Heat Recovery Fresh Air Handling Units
Model TypeAir Flow Efficiency of Heat Exchange%Noise Weight Dimensions(W*L*H)
 Enthalpy EfficiencyTemperature Efficiency
m³/hCoolingHeatingCoolingHeatingdB(A)kgmm
HQD05500656872783136950*1100*400
HQD08800656872783548950*1100*400
HQD1010006568727838561100*1200*400
HQD1212006568727838701400*1200*500
HQD15150065687278391001480*1300*500
HQD20200065687278421501480*1300*580
HQD25250065687278482201600*1400*580
HQD30300065687278503201700*1400*580
HQD40400065687278524001800*1600*580
HQD50500065687278555001900*1400*750
HQD60600065687278586902000*1800*750
HQD80800065687278587502200*1400*750
HQD1001000065687278588002300*2000*880
HQL1201200065687278628501650*1500*1800
HQL1501500065687278629201800*1500*1800
HQL1801800065687278659802000*1800*2000
HQL20020000656872786510802250*2000*2200
HQL25025000656872786812002400*2000*2400

Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling Unit
Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling Unit
Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling Unit
Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling Unit

Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling Unit
Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling Unit
Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling Unit
Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling Unit

Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling Unit
Heat Recovery Unit / Energy Recovery Ventilation Units Air Handling Unit
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours