Cureus | Unexpected Difficult Airway Management in a Grossly Malformed Newborn Baby With Tessier Cleft After an Emergency Cesarean Section

2022-07-16 02:34:07 By : baihe yang

"Never doubt that a small group of thoughtful, committed citizens can change the world. Indeed, it is the only thing that ever has."

Cureus is on a mission to change the long-standing paradigm of medical publishing, where submitting research can be costly, complex and time-consuming.

difficult airway management, neonatal airway management, neonatal airway, tessier cleft, congenital anomaly, congenital malformation, difficult airway

Shipra Tandon, Mridul Dhar , Amrita Bannerjee

Cite this article as: Tandon S, Dhar M, Bannerjee A (July 13, 2022) Unexpected Difficult Airway Management in a Grossly Malformed Newborn Baby With Tessier Cleft After an Emergency Cesarean Section. Cureus 14(7): e26832. doi:10.7759/cureus.26832

Emergent obstetric deliveries may present the anesthesiologist with a unique challenge of managing the airway of previously undiagnosed syndromic or malformed newborns in the obstetric theatre. The present report describes an emergency cesarean section in a 32-year-old lady who delivered a newborn with grossly anomalous features, the challenges in airway management in the newborn, and a discussion on preparation and sensitization about encountering such scenarios for the anesthesiologist and the associated medical teams.

Enhanced perinatal obstetric care and increased scope and coverage of these services in peripheral and remote regions have led to earlier recognition of congenital anomalies and timely termination if indicated. However, often un-booked cases end up in hospitals at the time of delivery or in labor in an emergent setting [1]. This may pose a unique challenge to the treating physician in terms of airway management in a newborn with malformed facial features. A case of airway management is described in a newborn baby with bilateral Tessier cleft and hydrocephalus following an emergency cesarean section.

An emergency cesarean section was scheduled for a 32-year-old, gravida 3, para 2 + 1 patient with a history of consanguineous marriage and a previous cesarean section because of scar tenderness. This was an un-booked case with no investigations including antenatal ultrasound. The pre-anesthetic evaluation revealed no major issues in the mother (American Society of Anesthesiologists physical status class II-E). The patient was taken for surgery and was given 2.2 mL (11 mg) of 0.5% injection of hyperbaric bupivacaine via spinal anesthesia in the left lateral decubitus position. The baby was delivered within five minutes of the lower abdomen transverse incision and was handed over to the neonatologist receiving the baby.

The delivered newborn appeared to have grossly anomalous features and required urgent airway management by the neonatology team. On visual appearance, the neonate had an exposed bulging left eye and severe hydrocephalus (Figure 1). Nasal and oral structures could not be appreciated. Vitals signs were heart rate of 68/minute and oxygen saturation of 85%, with an APGAR (appearance, pulse, grimace, activity, and respiration) score of 3. Because of such distorted anatomy, the assistance of the anesthesiology team was sought. Conventional bag-mask ventilation was not possible due to the facial defect. A larger mask covering the whole orifice of the defect was attempted with minimal success but was able to sustain the oxygen saturation to around 90%. Direct laryngoscopy with a Miller straight blade (size 1) was attempted first with supplemental oxygen given via a catheter resting in the oropharyngeal area, but nothing could be visualized as the blade put pressure on the eyeball directly, impeding proper laryngoscopy and glottic vision. The smallest available supraglottic airway (SGA) device was attempted (i-gel® size 1, Intersurgical Ltd., Wokingham, UK) but it failed to provide any seal to transmit the ventilation. While further expert help was sought with the arrangement of surgical airway access, another attempt of laryngoscopy was done with a Macintosh curved blade (size 1), which was fortunately successful in inserting the endotracheal tube (3 mm internal diameter) into what appeared to be the glottic opening. Tube position was confirmed by chest rise and auscultation. The baby was transferred to the neonatal intensive care unit for further management but did not ultimately survive because of the gross congenital anomalies and possible associated cardiac defects. The diagnosis of the craniofacial defect established later was Tessier cleft 3 on the left and 3, 4, and 6 on the right side (Figure 1).

Newborns with facial clefts can present with varying levels of airway difficulty based on the type and extent of the deformity [2,3]. In cases such as the present case, it is difficult to identify the correct location of the glottis while performing conventional laryngoscopy, as the nearby anatomical relations like the uvula, tongue, palate, and epiglottis may also be distorted. In this case, the exposed eyeball also impeded the correct placement of the laryngoscope blade. During airway management of newborns, the primary technique is often conventional Miller blade laryngoscopy, even if the airway is considered difficult [2,4]. If unsuccessful, alternate techniques like video laryngoscope (if available) and SGA insertion can be attempted with the aim to maintain oxygenation and ventilation [4]. Although in the present case SGA failed to provide adequate seal and ventilation, it is an invaluable device in such cases. Invasive surgical access to the front of the neck and specialist otorhinolaryngology help should be sought as a last resort rescue technique if all other methods fail [2,5].

In routine elective operative cases involving neonates and older children, the anesthesiologist has an opportunity to assess the airway, devise the airway management plan, and arrange the associated equipment. In the present case, the airway management in addition to being difficult was also relatively unexpected, as prior details of the baby’s syndromic condition were not known. In this context, it is perhaps prudent to have neonatal difficult airway equipment and cricothyroidotomy options on standby in obstetric operation theatres even if not used routinely [6]. This is important, especially for centers that often get emergent cases with no prepartum evaluation of the baby’s condition.

Teamwork and good communication with the obstetric and the neonatology team are very essential to have a favorable outcome in such cases, especially in this scenario where the anesthesiologist has to take care of the mother under anesthesia as well as assist the pediatrician/neonatologist in airway management of the newborn baby [4]. Intermittent training and debriefing of teams working in the obstetric theatre should be performed to sensitize them regarding encountering such scenarios and increase awareness of similar possibilities in syndromic newborns with other craniofacial anomalies associated with respiratory distress [2,5]. This should help in better team dynamics and coordination during the time of an acute airway emergency.

Anesthesiologists involved in obstetric anesthesia might encounter such emergent cases rarely and could be relatively unprepared for difficult airway management. The neonate in the current case in most likelihood was not compatible with life and would have had a poor outcome irrespective of airway management. Anesthesiologists and other team members involved in obstetric cases should strive to be adequately prepared to encounter such cases and manage the airway of syndromic or malformed babies with a coordinated team approach.

Department of Anesthesiology, All India Institute of Medical Sciences, Rishikesh, IND

Department of Anesthesiology, All India Institute of Medical Sciences, Rishikesh, IND

Department of Anesthesiology, All India Institute of Medical Sciences, Rishikesh, IND

Human subjects: Consent was obtained or waived by all participants in this study. Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following: Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work. Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work. Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.

The authors thank Dr. Srinivas Gosla Reddy for his help in establishing the diagnosis of the case.

Tandon S, Dhar M, Bannerjee A (July 13, 2022) Unexpected Difficult Airway Management in a Grossly Malformed Newborn Baby With Tessier Cleft After an Emergency Cesarean Section. Cureus 14(7): e26832. doi:10.7759/cureus.26832

Peer review began: June 30, 2022 Peer review concluded: July 07, 2022 Published: July 13, 2022

© Copyright 2022 Tandon et al. This is an open access article distributed under the terms of the Creative Commons Attribution License CC-BY 4.0., which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Scholarly Impact Quotient™ (SIQ™) is our unique post-publication peer review rating process. Learn more here.

This link will take you to a third party website that is not affiliated with Cureus, Inc. Please note that Cureus is not responsible for any content or activities contained within our partner or affiliate websites.

Scholarly Impact Quotient™ (SIQ™) is our unique post-publication peer review rating process. SIQ™ assesses article importance and quality by embracing the collective intelligence of the Cureus community-at-large. All registered users are invited to contribute to the SIQ™ of any published article. (Authors cannot rate their own articles.)

High ratings should be reserved for work that is truly groundbreaking in its respective field. Anything above 5 should be considered above average. While all registered Cureus users can rate any published article, the opinion of domain experts is weighted appreciably more than that of non-specialists. An article’s SIQ™ will appear alongside the article after being rated twice and is recalculated with each additional rating.

Visit our SIQ™ page to find out more.

Scholarly Impact Quotient™ (SIQ™) is our unique post-publication peer review rating process. SIQ™ assesses article importance and quality by embracing the collective intelligence of the Cureus community-at-large. All registered users are invited to contribute to the SIQ™ of any published article. (Authors cannot rate their own articles.)

Already have an account? Sign in.

Please note that by doing so you agree to be added to our monthly email newsletter distribution list.

By joining Cureus, you agree to our Privacy Policy and Terms of Use.